The Propaq LT is specially designed to extend continuous monitoring capabilities to care areas where technical complexity or cost made it impossible in the past. Legendary Propaq quality and reliability in a compact, lightweight and easy-to-use monitor. Featuring both continuous and spot check monitoring, the Propaq LT is ideal for both hospitals and outpatient surgery facilities for simple procedures, pre- and post-operative care and transport. Frontline caregivers all over the world are caring for growing numbers of more acutely ill patients. At the same time, a critical shortage of clinicians face increasing requirements for higher care standards and regulations. How will today’s healthcare providers meet these increasing challenges? With advancements in technology that offer new paradigms of care. The Propaq LT marks such an advancement. For a little more than half the price of a traditional bedside monitor, the Propaq LT allows caregivers to extend continuous monitoring to areas never covered before. Appropriate for transport, ambulatory, and bedside monitoring applications, the Propaq LT has the versatility to meet your needs. Its simple and highly intuitive user interface allows highly skilled or less skilled clinical staff to operate the monitor with ease. The Propaq LT can even be uniquely configured for a particular care area. With all this, the new Propaq LT is the perfect solution for today’s fast-paced frontline hospital environment. - 3- or 5-lead ECG, SpO2, Smartcuf NIBP, pulse rate, respiration
- Spot check and continuous vital signs monitoring
- Neonatal, pediatric and adult modes
- Neonatal, paediatric, and adult patient modes
- Masimo SET motion-tolerant SpO2 or Nellcor SpO2
- Highly intuitive, easy-to-use, user interface:
- Custom configurable to user care area
- Operates in spot-check and/or continuous monitoring modes
- Direct-action operation with camcorder-type controls
- Three display modes to accommodate varying user skill-sets
- Colour Transflective LCD screen, viewable indoors and outdoors
- 24-hour tabular and graphical trending
- Stores up to 20 full-disclosure data snapshots
- Transfers trends and snapshots to PC for printing
- Print 8.5" x 11" reports or attach a PDF report to an EMR via USB connection to a PC
- Wireless connectivity to Acuity Central Station (hospital) and Mobile Acuity (disaster relief) via FlexNet
- A compact design weighing less than 1 kilo, about the size of the average paperback book
- Shock resistance of up to 75 g, enough to withstand a 1.8 m drop
- U.S. Military flight-certified for fixed- and rotary-wing aircraft
- 2 year warranty
General - Available in two configurations:Standalone: model 802LTONNetworked via wireless radio: model802LTRN
- Adult, paediatric and neonatalpatient modes
- Electrosurgery interference suppression(ESIS): all channels except impedancerespiration
- All channels electronically isolated
ECG - Automatic 3- and 5-lead monitoring andcable type detection
- Selectable leads: I, II, III, aVR, VL, VF, V
- Lead fault detection and autoconfigure
- Bandwidth:
- Adult: 0.5 to 80 Hz monitor mode; 0.05 to 80 Hz extended mode
- Paediatric/neonate: 0.5 to 80 Hz monitor
mode; 0.05 to 80 Hz extended mode - Hypertronics connector
- Heart rate measurement range:25 to 300bpm (display)
- Heart rate accuracy: ± 3bpm or 3%
- Pacer detection and display
- Electrosurgery and defibrillator protected
- Sweep speed: 25 mm/sec; (6.25 mm/secrespiration only)
- User-selectable size (mV/cm):8, 4, 2, 1, 0.5, 0.2
- QRS tone: med/low/off
- 3.0 sec waveform duration at 25 mm/sec forsingle waveform; 6.0 sec waveform durationat 25 mm/sec for cascading waveform
- QRS detector range:
- Adult or paediatric mode: 0.22 to 5.0 mV(RTI)
- Neonatal mode: 0.1 to 5.0 mV
- Neonatal width: 40 to 120 msec
- Paediatric width: 40 to 120 msec
- Adult width: 70 to 120 msec
NIBP - Oscillometric method
- Automatic (intervals between 1 to 60min)and manual modes
- Quick-action NIBP start/stop button
- TurboCuf: 5min of repeated NIBP readings
- Systolic, diastolic and mean display
- On-screen manometer
- Store and view up to 150 readings
- Standard cuff sizes:Neonates #1 to #5, infant, child, small adult,adult, large adult, thigh
- Cuff overpressure protection
- Typical measurement time: 30 to 45 sec
- Smartcuf motion-tolerant NIBP technology
- Blood pressure range:
- Adult:
- Systolic: 30 to 260 mmHg
- Diastolic: 20 to 235 mmHg
- Mean: 20 to 255 mmHg
- Paediatric:
- Systolic: 30 to 160 mmHg
- Diastolic: 15 to 130 mmHg
- Mean: 15 to 140 mmHg
- Neonate:
- Systolic: 25 to 120 mmHg
- Diastolic: 10 to 105 mmHg
- Mean: 10 to 110 mmHg
- Blood pressure target inflation:
- Adult: 160 mmHg
- Paediatric: 120 mmHg
- Neonate: 90 mmHg
- Pulse rate accuracy: ± 3 bpm or 3%
- Pulse rate range: 30 to 220 bpm
SpO2 (Masimo) - Masimo SET technology
- Perfusion Index and Signal IQ display
- Sensitivity modes: Normal, MAX, APOD
- Masimo SET sensors
- Waveform and pulse amplitude meter
- Pulse tone pitch indicator
- Saturation range: 1 to 100%
- Probe accuracy: 25 to 41 °CNo motion:Adult/Paediatric: 70 to 100% ±2 digits0 to 69% unspecifiedNeonatal: 70 to 100% ±3 digits0 to 69% unspecifiedDuring motion:Adult/Paediatric/Neonatal:70 to 100% ±3 digits0 to 69% unspecified
- Pulse rate measurement range:(Adult/Paediatric/Neonatal):No motion: 26 to 239 bpmDuring motion: 26 to 239 bpm
- Pulse rate accuracy:No motion: ±3 digitsDuring motion: ±5 digits
SpO2 (Nellcor) - Nellcor OxiMax sensors
- Waveform and pulse amplitude meter
- Normal, fast and slow response modes
- Saturation range: 1 to 100%
- Accuracy: (Probe: 70 to 100%, 28 to 42 °C)Adult/Paediatric digit: ± 2 countsNeonate digit: ± 3 counts
- Pulse rate accuracy: no motion: ± 3 bpm
- Pulse rate range: 25 to 300 bpm
| Respiration - Breath rate source: impedance pneumography
- Two user-selectable leads: RA-LA, RA-LL
- Automatic cardiovascular artifact (CVA)rejection
- Respiration rate range:Adult/Paediatric modes: 2 to 150 br/mNeonate mode: 3 to 150 br/m
- Respiration detection threshold: 175milliohms or 2X CVA, whichever is greater
- Respiration rate accuracy: ± 2 br/m or ± 2%
- Sweep speed: 6.25 mm/sec
Physical - MonitorHeight: 137.1 mmWidth: 190.5 mmDepth: 53.3 mmWeight: 904.3 g with FlexNet radio;765 g without radio
- Charging stationHeight: 144.7 mmWidth: 193 mmDepth: 152.4 mmWeight: 680.3 g
- Colour display
- 3.5 in colour transflective LCD
- Viewable in direct sunlight
Environmental - Operating temperature: 0 to 40 °C
- Operating relative humidity: 5 to 95%,noncondensing
- Monitor operating altitude: -610 to 4,572 m
- Cradle operating altitude: 152 to 4,572 m
- Shipping/storage temperature: -20 to 60 °C
- Shock: 75 g
- Vibration, Random and Sinusoidal:designed to meet RTCA/DO-160D, categoriessection 8 modified
- Electromagnetic compatibility (EMC): per IEC601-1-2
- Drip-proof per IEC 529, level IPX1
Power - Rechargeable lithium ion internal battery pack
- External recharger
- Input voltage: 12 to 28 VDC
- AC power adapter: 110 and 220 V, DCvehicle conversion
- Operating time on battery, typical*: ECG/Responly: 24 hours; ECG/Resp, SpO2 and NIBP:8 hours
- Battery recharge time: < 3 hoursPerformance may vary based on monitorconfiguration and battery condition* Fully charged, new battery at 25°C, NIBP every 15minutes, display and backlight operating in powersave mode.
Communications - PC UtilityUSB interface via charging stationSupports Microsoft Windows XP/2000and laterAutoprint utility allows printing of tabulartrends and snapshots to connected laserprinter
- Acuity CentralStation Wireless FlexNet Network802.11a, 5 GHzAble to operate on shared 802.11a/b/gnetwork
Alarms - All parameters: upper/lower limits specific topatient mode
- Factory default or programmable settings forall patient modes
- Alarm indicator: red
- Alarm(s) off indicator: yellow
- Audible alarm tone: high/med/low
- Alarm silence/reset: 90 sec
- One-button “Param-set” for adjustingspecific parameter alarm limits,programmable
- Equipment alert: yellow
Trends - Tabular numeric and graphical formats
- All parameters trended/viewable
- Resolution: non-NIBP trends enteredevery 1 min
- NIBP trends entered after each reading
- Duration: 24 hr non-NIBP trends; up to 150NIBP readings
- Page up/down trend view
- Up to 20 data snapshots (7 sec behind and14 sec ahead of snapshot event) of displayeddata captured
Certifications/Standards - Complies with all relevant AAMI, IEC, EN,CSA, and UL standards. CE marked accordingto the European Medical Device Directive.CSA certificate of compliance for use in theU.S. and Canada
Warranty - Monitor and recharger: two years
- Accessories: 90 days
- Extended warranties available
All Propaq vital signs monitors come standard with Smartcuf technology, a new standard in NIBP accuracy. This patented software offers industry-leading performance and accuracy in the presence of motion artifact. |
|
|
|
|
Follow us on