Monitor all of your patient’s vital signs with the innovative SunTech 247 Diagnostic Station. This complete system offers automated blood pressure reading with an optional manual mode, in addition to temperature and pulse oximetry (SpO2). With all these features and the convenience of a portable stand, the SunTech 247 Diagnostic Station truly offers unrivaled performance.
Automated blood pressure reading can save a lot of time, but it’s less reliable with pediatric patients, individuals with arrhythmias, and in moving vehicles. This diagnostic station is the first clinical grade automated blood pressure device that also gives you the option of a manual mode so it is perfect for every situation. The modular design allows you to add or remove the temperature and SpO2 monitors as needed. A variety of mounting options ensures that you can set up the SunTech 247 Diagnostic Station to fit your needs. 10 cuff sizes are available, ranging from child to thigh, to ensure the perfect fit for all of your patients.
The SunTech 247 is intended for patients ages 3 and up Includes:
- Adult & Large Adult All Purpose Cuffs
- 8' blood pressure hose
- SpO2
- Reusable Adult Finger Sensor
- Temperature
- Oral/Axillary probe (blue)
- 1 box of Filac Fastemp™ probe covers
- Rechargeable battery
- Mobile stand
- Basket
- Mains/Power Supply
- Mains/Power Cable
- Resource CD
- Quick Start Guide
- Reference Card
• Patient population: Adult and pediatric patients (age 3 and above)
• Method of measurement: Oscillometric
• Initial inflation pressure: 160mmHg +/- 20mmHg
• Blood pressure range (mmHg): Blood pressure range (mmHg)
• Blood pressure accuracy: Measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Electronic or automated sphygmomanometers.
• Blood pressure determination time: 35-40 seconds typical for Adult cuff
• Heart rate range: 30-200 bpm +/- 2% or +/- 3 bpm, whichever is greater
• Temperature range: 86°F (30.0°C) – 109.4°F (43.0°C)
• Temperature accuracy: +/- 0.2°F (+/-0.1°C)
• Functional oxygen saturation range: 40-100%
• Functional oxygen saturation accuracy: 70-100% +/- 2 digits
(Note: because pulse oximeter equipment measurements are statistically distributed, only about two-thirds of pulse oximeter equipment measurements can be expected to fall within ± 2 digits of the value measured by a CO-oximeter.)
• Operating conditions: 10°C (50°F) to 40°C (104°F) Less than 95% RH
• Storage conditions: -20°C (-4°F) to 50°C (122°F) Less than 95% RH
• Power: External power supply for non-battery version: Globtek model: GTM21089-1506-T3 (SunTech part number: 19-0013-00). External power supply for Battery version, rechargeable by Globtek model: GTM21089-1509-T3 (SunTech part number 19-0014-00)
• Calibration: Check once per year for BP and Temperature
• Safety systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 330 mmHg. Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
• Dimensions: Length = 5.5 inches, Height = 11.5 inches, Width = 3.8 inches; Length =14.0 cm, Height = 29.2 cm, Width = 9.7 cm
• Standards: UL60601-1, CAN/CSA C22.2 601-1, IEC 60601-1, IEC 60601-1-2 (EMC), IEC 60601-1-4, ISO 9919, AAMI SP10:2002, ASTM E 1112, EN 12470-3. Meets “Non-invasive Sphygmomanometers — General Requirements & Supplementary Requirements for Electro-Mechanical BP Measuring Systems”, EN 1060-1, EN 1060-3
• Classification: Protection against electric shock: Class II (for non-battery version), Internally Powered Equipment (for battery version); Applied parts: Type BF; Mode of operation: Continuous
|
|
|
|