Featured Items
QBC Accutubes, Box/100
$$405.00
Learn More
QBC AccuTubes are for use with the QBC Autoread Plus. 70 µl. sample size. Both capillary & venous (using QBC pipetter) blood can be used with this tube. Features a pre-inserted, ventilated stopper. Floats are externally contained in the AccuTube packaging within soft grip holders. Slide the AccuTube through the soft grip holder, and the float will be inserted. Anticoagulant included in tube.
|
|
Laboratory Centrifuge-6 Place
$$317.00
Learn More
This affordable single speed centrifuge is designed for blood separation in a small lab or physician office.
• Compact design (8.5in x 11in x 12.5in)
• Lid Safety Latch: System will not run with lid open
• Brushless motor for smooth quiet operation with no routine maintenance
• Clear Lid: Offers safe sample observation
• Nominal Speed 3150 RPM(+/ - 100)
• Capacity: Six (6) 15ml test tubes up to 17mm x 125mm
Includes:
• Six 75 mm tube holders
• Six 100mm tube holders
• Six 125mm tube holders
• User Manual
• 1 Year Warranty
|
Endocell Sampler Box/35
$$121.00
Learn More
The Wallach Endocell offers simplicity, safety and economy to the screening process for endometrial carcinoma and precancerous conditions. Using manual suction, it extracts a histological sample from the uterine mucosal lining in seconds. It is also an excellent monitor for the effects of hormonal therapy and a valuable diagnostic tool for fertility problems and uterine pathogens. It can be utilized for endometrial biopsy, suction type and menstrual extraction.
|
|
|
ESR Dispette® 2 w/ Pre-Filled Reservoirs, Box/10
$$56.05
Learn More

Precision Components Dispette 2 components are known for quality, an important factor linked to test outcomes. High precision polystyrene tubes, sourced from Switzerland, ensure a minimum internal bore of 2.55mm to prevent “cell bouncing” or the impedance of proper cell sedimentation. The precise reproducibility of the tube also helps to avoid variances in physical handling. Protective Aerosol Barrier The “triple plug” tip design provides a unique protection barrier from accidental over-filling of the pipette tube and spillage of blood. Superior Reservoir Interface The pierceable reservoir cap provides greater tactile feedback during pipette insertion. A “sealing” ring molded into the reservoir below the fill line ensures correct filling when inserted into the reservoir and also helps to prevent leaks. The restricted end of the reservoir acts as an extra safety feature by indicating the pipette tube is at its correct position. Features - Protective grommet
- Chamber for excess blood
- Cotton plug
- Defined mm scale
- Shatterproof polystyrene tube
- Consistent internal bore
- Precision product made in Switzerland
- CLIA-waived test category
- Pierceable cap with enlarged mixing space
- Sealing ring
- Transparent polyethylene reservoir
- 0.25ml of 9% saline
- Restricted end
|
Microhematocrit Capillary Tubes, 100/Vial, 12 Vials/Box
$$52.95 $58.00
Learn More
Provides accurate reproducible readings. Anticoagulant tubes with ammonium heparin. Fire polished tips are easily sealed by flame, clay or patented caps. Tubes are color coded for easy identification: red for heparinized and blue for plain tubes. Length: 75 mm. 100 tubes/vial. - Heparinized: I.D. 1.1–1.2 mm., Wall 0.2 ±0.02 mm.
- Plain: I.D. 1.1–1.2 mm., Wall 0.2 ±0.02 mm.
|
|
BBL™ Taxo™ Discs, Cartridge/50
$$8.25
Learn More

Taxo A discs are for the presumptive identification of group A beta-hemolytic streptococci based on susceptibility to a low level of bacitracin. Discs are intended for use with pure cultures. Taxo A discs are not for use directly with clinical specimens or other sources containing mixed flora. The organism to be presumptively identified must first be isolated as separate colonies by streaking the specimen onto appropriate culture media; e.g., Trypticase Soy Agar with 5% Sheep Blood (TSA II). However, the BBLGroup A Selective Strep Agar with 5% Sheep Blood (ssA) plate, which may be used for the primary isolation of group A streptococci from throat specimens, was designed specifically for use with the Taxo A disc. Taxo A discs are impregnated with a low level of bacitracin. According to the work of Maxted, of Levinson and Frank, and others, the group A streptococci may be differentiated from the other Lancefield groups of hemolytic streptococci by the formation of a zone of inhibition around the disc. Group A beta-hemolytic streptococci are sensitive to small amounts of bacitracin, while betahemolytic streptococci of other serologic groups are more resistant. The Taxo A disc on a blood agar plate can be used for presumptive identification of group A beta-hemolytic streptococci after overnight incubation.
|
Microscope Slides, 3 x 1, Box/72
$$4.50 $4.95
Learn More
• Exceptionally clear, water-white, extra hard glass. • Rounded corners, ground and polished edges. • Non-corrosive and non-fogging. • Pre-Cleaned • Thickness: 0.9 to 1.0 mm.
Image for illustration purposes only.
|
|
|
|