Graham Fields’ GRAFCO External Fetal Monitor provides vital monitoring of fetal heart rate and uterine contractions. Provide this integral aspect of antenatal care easily and comfortably with a non-invasive ultrasound Doppler and external TOCO. Perform non-stress tests or monitor the progress of labor to ensure the safety of the fetus. This unit is an essential piece of equipment for clinics, Ob-Gyn’s offices, and hospitals.
The GRAFCO External Fetal Monitor uses a nine–crystal broadband pulsed wave transducer to detect the fetal heartbeat and ensure that the fetus is not in distress. TOCO monitoring measures uterine contractions. Remote marker automatic fetal movement recognition records gross fetal movements. Other features include FHR1 and FHR2 monitoring and automatic transducer identification.
Health care providers can easily assess the status of the patient and fetus. A large, adjustable LCD display shows a real time heart rate and cardiotocograph, in addition to 12-hour monitoring trends and playback. An audible and visual alarm will warn you if the fetal heart rate goes above or below specified limits. The built-in thermal line recorder provides important documentation of fetal heart rate and uterine activity.
Features:
- 4.1" x 3.1" adjustable LCD
- Build-in thermal line recorder
- Nine–crystal broadband pulsed wave transducer
- FHR1 and FHR2 monitoring
- Remote marker automatic fetal movement recognition
- TOCO monitoring
- Real-time displaying cardiotocography (CTG), 12-hour monitoring trends, and playback
- Audible and visible alarm with upper and lower alarm limits settings
- Automatic transducer identification
- Z-fold paper
- Dimensions: 13.0 W x 10.6 D x 3.9 H in. (330 x 270 x 100 mm)
- Weight: 7.7 lb (3.5 kg)
Safety - Complies with: IEC 60601-1, IEC 60601-1-2, EN 55011, IEC 1157, YY 0449-2003
Display: - Backlight: Cold cathode fluorescent
- Active Area: 4.1W x 3.1 H in. (103.0 x 79.0 mm) (320 x 240 dots)
- Resolution: 85 dots per inch
Printing: - Recording Paper: Z-fold, thermal
- Printing Width: 4.4 in. (112mm)
- Paper Advance Speed: 1cm/min, 2cm/min, and 3cm/min (optional)
Contraction(External TOCO) - TOCO Range: 0% - 100%, 135g strength corresponding to 100%
- Sensitivity: 3.7uV/V/mmHg
| Marking: - Manual fetal movement marking
Ultrasound Transducer: - System: Pulsed Doppler
- Weight: .35lb (160g)
- Cable Length: 98 in (2.5m)
- Dimensions: 3.5 x 2.6 in. (90mm x 65mm)
- Latex Free
TOCO Transducer: - System: Passive Strain Gauge
- Weight: .33lb (150g)
- Cable Length: 98 in (2.5m)
- Dimensions: 4.0 x 2.0 in. (102 x 50 mm)
- Latex Free
Remote Marker - Length: 98 in (2.5m)
- Weight: .12 lb (56g)
|
|
|
|
|